IWAKI high techno pump IX series
It supports the needs of every medicine note spot.
The pro-evolution fixed-quantity pump birth that realized high-precision control
Hi-tech pump (high-precision fixed-quantity pump) IX series
Wide control is
I realized the control ratio of 1:750 by letting discharge/suction speed have variableness by a control motor. I can control it in the range of to up to 150L/hr from a very small amount of 200mL/hr.
Energy saving, ECO driving
By the adoption of high efficiency copter Cal gear and the assist spring, I realized about 70% of electricity consumption cuts with equal performance for the company frequent use motor fixed-quantity pump (springback mechanism).
High-precision fixed-quantity infusion
I realized ±1% while adopting low-priced chokudo diamond Fulham structure by the valve design that was the high efficiency that precision did not decline at the time of the microinjection either and a combination of discharge/suction speed control with the control motor.
World correspondence
It supports the power supply of all the countries of the world by a free power supply (AC100-240V). In addition, I meet American UL standard and European safe standard CE.
It becomes waterproofing, the dust proofing structure of IP65 by making seal structure for each drive, controller part. (the outdoors I cannot use it.)
It becomes waterproofing, the dust proofing structure of IP65 by making seal structure for each drive, controller part. (the outdoors I cannot use it.)
High compression, high efficiency pump part
Pumps always operate in the full stroke head and maintain high compression ratio. It became the pump which was superior in ketsukajikyuseino and did not do gas rock.
Uniform low shock infusion
The medicinal solution infusion that is uniform even if discharge is in state that there is few it is possible that absorbing time is constant and controls driving speed by discharge time. Furthermore, the shock (inertial force) decreases, too, and load to the discharge side plumbing decreases.
Safe design
In consideration of the environmental pollution by the on-site security and medicine leak, it was shipped with diamond Fulham damage analyzer. In addition, of the discharge pressure by the plumbing confinement of the emergency, in the case of abnormally increasing it, an abnormal load detective function acts, and protect a pump and a pipe safely.
Furthermore, I get a wrong group of the valve and consider the small safety including the drain mouth at the time of adoption of the prevention structure and the diamond Fulham damage.
Furthermore, I get a wrong group of the valve and consider the small safety including the drain mouth at the time of adoption of the prevention structure and the diamond Fulham damage.
Pump outline specifications (50/60 Hz)
Discharge
| 0.2 - 150 L/hr
|
The best discharge pressure
| 0.4 MPa
|
Main materials
| PVDF (IX-C150TC/TE), SUS316 (IX-C150S6)
|
Connection
| Screw (R3/4 or 3/4NPT)
Flange (JIS10K 20A or DIN PN16 DN20) |
Liquid temperature range
| TC/TE: It is 0-80 degrees Celsius 0-50 degrees Celsius, S6
|
The best transportation viscosity
| 1000mPa, s
|