Move to the text

MINEBEA

Road cell CC010 series for the keiju system

Automatic model canister type road cell to align

It is most suitable for Hopper tank scale, keiju system
High-precision high trust
(OIML-D1 equivalency: fault straightness + hysteresis + repetition-related =0.04%R.O.)
All stainless steel sealing structure that are superior in the environment-resistant nature
All capacity equivalence dimensions (height, outer diameter)
※An automatic model to align: The system where I am going to always return centers of gravity to for rolling of tank and Hopper perpendicularly

Specifications

Rating capacity
4.903kN{500kgf} - 490.3kN{50tf}
I permit it and overload it
150%R.C.
I overload a limit
200%R.C.
The rating output
2mV/V±0.002mV/V
Precision
0.04%R.O.
Creep
0.03%R.O./20min
Zero return
0.03%R.O./20min
Temperature cover
-10 degrees to 50 degrees
Allowable temperature range
-20 degrees to 70 degrees
0 points of temperature influence
0.028%R.O./10 degree
Temperature influence of the output
0.03%LOAD/10 degree
Cable
Is with φ 7, 4 core shields, a 5m connection, tip Yanagi Line (CC010-5T - 50T:10m)
Protection class
IP68

TGE series techno graph

New desk testing equipment of the high-precision tall handloom ability, simple operation

Highly precise
±0.5% (JIS 0.5 grade) of the ±1% (the JIS first grade) or instructions level of the instructions level are available in the range of 1/1-1/500 of the road cell capacity

High function, simple operation
It is correspondence for the analog output of road cell automatic span adjustment, one-touch automatic zero, an examination origin automatic return function (overshot reply), examination condition registration, any setting manual speed (3 speed), an examination power, the position, a pulling compression continuation repetition examination

Light weight, compact
I reduce mass 50 kg than conventional products (comparison with GT-10kN) and shorten width 100mm

Specifications

Model
TGE-10kN
TGE-5kN
TGE-1kN
TGE-500N
TGE-200N
Examination measurement of the force range note 1)
0.1Nto10kN
0.1Nto5kN
0.1Nto1kN
0.1Nto500N
0.1Nto200N
Examination measurement of the force precision
With pulling, compression, the bending test in the range of 1/1-1/500 of the road cell capacity
Less than ±1% (the = JIS 0.5 grade that produces the high-precision article within ±0.5% of the instructions level by separate sale) of the instructions level
Conformity standard
First grade or 0.5 grade of JIS B 7721, class 1 of ISO7500-1
Or it is 0.5, grade of BS 1610 or 0.5, ASTM E4, class 1 of DIN 5122
Effective examination width note 2)
(mm)
420 (with a lead screw protective cover)
Crosshead stroke
(mm)
1100 (as for the maximum installation distance 1180)
Pulling stroke
(mm)
700
(CH/CHT-10kN
At the time of wearing)
800
(at the time of CH-5kN wearing)
850
(at the time of CH-1kN wearing)
880
(at the time of CH-1kN wearing)
900
(at the time of CH-200N wearing)
Cross-head speed
(mm/min)
0.1, 0.5, 1to500 (it can be configured by 1mm/min pace during this period)
Cross-head speed
Either big value of ±0.5% of the precision setting speed or ± 0.0025mm/min
Speed-setting method
Manual operation: I input a number with an operation panel (it can be configured by 0.1, 0.5, 1 - 500mm/min pace),
A use of PC: I am automatically set by the examination condition that I made
Manual speed
3 speed of H/M/L, each speed are configurable optionally
Examination mode
A single, the For Sale according to the cycle (examination power, pair of the position): Creep, automatic load
Indication
An examination power: Five columns of digital indication ±99999, peak and break examination power indication is possible,
A position: 51/2 digital indication ±1999.99, precision: But, less than 0.1% of the instructions level, it is ±0.01mm in ±10mm or less
Function attached to the standard
Road cell capacity: Automatic distinction, a road cell span: I pull it and compress it and automatically set it,
A road cell zero point: A one push, position reset: One push,
Movement at the time of the sample break detection: I choose a stop, inversion, one of the disregard,
Break detectivity: Any 0.1% - 9.9% of examination powers setting,
An examination condition registration function: 10 conditions,
An examination power, position analog output: DC0toDC5V (belonging to a scaling function),
Communication facility: USB interface 2.0/1.1 standard conformity, B type connector
External form dimensions (WxHxD)
(mm)
660x1581x503 (I do not include a level adjuster)
Mass
About 80 kg
Power supply voltage, frequency/
Power consumption
Single phase AC100Vto 15V, 50/60Hz/500VA
Use temperature humidity range
Temperature 5 degrees Celsius to40 ℃, humidity 20%to80%RH (thing without the dew condensation)
※R.C.(RatedCapacity) refers to rating capacity.
※The general precision refers to (nonlinear + hysteresis + temperature properties).

※The product specification mentioned above is data as of July, 2008. Please note that specifications, the production situation of the product may be changed without a notice.
Back to TOP